Search for a full or partial Catalog Number, CAS Number or description
Your favorites Quick Order Form
Your cart is empty.
Home Catalog New Products Custom Synthesis & CGMP Product Resources About
Contact Strem

CAS Number: 99604-67-8
Product Catalog

44-7880
Ruthenium Tris(acetonitrile)pentamethylcyclopentadienylruthenium(II) hexafluorophosphate, min. 98%
CAS Number: 99604-67-8
MDL Number: MFCD04117715
Molecular Formula: C16H24F6N3PRu
Molecular Weight: 504.42
Chemical Formula: [Ru(C10H15)(CH3CN)3]+PF6-
Color and Form: yellow orange pwdr.
Note:  

Stability: air sensitive, store cold

44-7880

Choose Your Country for Price and Stock Status

Choose Your Country

SECTION 1: Product Identification
Chemical Name: Tris(acetonitrile)pentamethylcyclopentadienylruthenium (II) hexafluorophosphate, min. 98%
Product Number: 44-7880
CAS Registry Number: 99604-67-8
Formula: [Ru(C10H15)(CH3CN)3]+PF6-
EINECS Number: none
Chemical Family: metallocene
Synonym: none
SECTION 2: Composition and Information on Ingredients
Ingredient CAS Number Percent ACGIH (TWA) OSHA (PEL)
Title compound 99604-67-8 100 2.5mg/m3 (as F) 2.5mg/m3 (as F)
SECTION 3: Hazards Identification
Emergency Overview: Irritating to skin, eyes and respiratory tract. May be harmful if swallowed.
Primary Routes of Exposure: Inhalation, skin, eyes
Eye Contact: Causes slight to mild irritation of the eyes.
Skin Contact: Causes slight to mild irritation of the skin.
Inhalation: Irritating to the nose, mucous membranes and respiratory tract.
Ingestion: No specific information is available on the physiological effects of ingestion. May be harmful if swallowed.
Acute Health Effects: Irritating to skin, eyes and respiratory tract.
Chronic Health Effects: Prolonged exposure to hydrolysable fluorine compounds can cause deterioration of bone and tooth structure.
NTP: No
IARC: No
OSHA: No
SECTION 4: First Aid Measures
Eye Exposure: Immediately flush the eyes with copious amounts of water for at least 10-15 minutes. A victim may need assistance in keeping their eye lids open. Get immediate medical attention.
Skin Exposure: Wash the affected area with water. Remove contaminated clothes if necessary. Seek medical assistance if irritation persists.
Inhalation: Remove the victim to fresh air. Closely monitor the victim for signs of respiratory problems, such as difficulty in breathing, coughing, wheezing, or pain. In such cases seek immediate medical assistance.
Ingestion: Seek medical attention immediately. Keep the victim calm. Give the victim water (only if conscious). Induce vomiting only if directed by medical personnel.
SECTION 5: Fire Fighting Measures
Flash Point: no data
Autoignition Temperature: none
Explosion Limits: none
Extinguishing Medium: carbon dioxide, dry powder or foam.
Special Fire Fighting Procedures: Fire fighters should be equipped with a NIOSH approved positive pressure self-contained breathing apparatus and full protective clothing.
Hazardous Combustion and Decomposion Products: If involved in a fire this material may emit organic fumes and toxic hydrogen cyanides and hydrogen fluoride gas.
Unusual Fire or Explosion Hazards: No unusual fire or explosion hazard.
SECTION 6: Accidental Release Measures
Spill and Leak Procedures: Small spills can be mixed with vermiculite, sodium carbonate or other suitable non combustible adsorbent and swept up.
SECTION 7: Handling and Storage
Handling and Storage: Keep material cold in a tightly sealed container. Prolonged exposure to the air will result in degradation of the product. Handle and store material under an inert atmosphere of nitrogen or argon.
SECTION 8: Exposure Controls and Personal Protection
Eye Protection: Always wear approved safety glasses when handling a chemical substance in the laboratory.
Skin Protection: Wear protective clothing and gloves.
Ventilation: Material may form a fine dust. If possible, handle the material in an efficient fume hood.
Respirator: If ventilation is not available a respirator should be worn. The use of respirators requires a Respirator Protection Program to be in compliance with 29 CFR 1910.134.
Additional Protection: No additional protection required.
SECTION 9: Physical and Chemical Properties
Color and Form: yellow to orange powder
Molecular Weight: 504.42
Melting Point: no data
Boiling Point: no data
Vapor Pressure: no data
Specific Gravity: no data
Odor: none
Solubility in Water: slightly soluble
SECTION 10: Stability and Reactivity
Stability: air sensitive (store cold)
Hazardous Polymerization: no hazardous polymerization
Conditions to Avoid: air, heat sources
Incompatibility: Air, oxidizing agents halogens, protic reagents
Decomposition Products: nitrogen oxides, carbon monoxide, organic vapors, hydrogen fluoride and ruthenium oxide.
SECTION 11: Toxicological Information
RTECS Data: No information available in the RTECS files.
Carcinogenic Effects: no data
Mutagenic Effects: no data
Tetratogenic Effects: no data
SECTION 12: Ecological Information
Ecological Information: No information available
SECTION 13: Disposal Considerations
Disposal: Dispose of according to federal, state, and local regulations.
SECTION 14: Transportation
Shipping Name (CFR): Non-hazardous
Hazard Class (CFR): NA
Additional Hazard Class (CFR): NA
Packaging Group (CFR): NA
UN ID Number (CFR): NA
Shipping Name (IATA): Non-hazardous
Hazard Class (IATA): NA
Additional Hazard Class (IATA): NA
Packaging Group (IATA): NA
UN ID Number (IATA): NA
SECTION 15: Regulatory Information
TSCA: Not listed in the TSCA inventory.
SARA (Title 313): Title compound not listed.
Second Ingredient: none
Third Ingredient: none
SECTION 16: Other Information
Disclaimer: The information herein is believed to be accurate and reliable as of the date compiled. However, Strem Chemicals, Inc. makes no representation, warranty, or guarantee of any kind with respect to the information contained in this document or any use of the product based on this information.
Preparation Date: 1/23/2004
Revision Date: 12/14/2011

Enter a lot number