CAS Number: 7440-02-0
Product Catalog

28-1916
Nickel Nickel (skeletal), unpromoted (supplied under water) (Actimet® M)
CAS Number: 7440-02-0
MDL Number: MFCD00011137
Molecular Formula:  
Molecular Weight:  
Chemical Formula:  
Color and Form: black pwdr. (d50=35 μm)
Note: Sold in collaboration with BASF for research purposes only.

Price Note: price per qty. contained

Safety: Hazardous

Please log in or choose your country below to view prices.

Choose Your Country

SECTION 1: Product Identification
Chemical Name: Nickel (skeletal), unpromoted (supplied under water) (Actimet® M)
Product Number: 28-1916
CAS Registry Number: 7440-02-0
Formula: Ni
EINECS Number: 231-111-4
Chemical Family: supported metal catalyst
Synonym: Raney nickel, nickel catalyst
SECTION 2: Composition and Information on Ingredients
Ingredient CAS Number Percent ACGIH (TWA) OSHA (PEL)
Title compound 7440-02-0 100 1.5mg/m3 (as Ni) 1mg/m3 (as Ni insoluble)
SECTION 3: Hazards Identification
Emergency Overview: May cause sensitization by skin contact. Possible harm to the unborn child and possible risk of irreversible effects. May cause cancer.
Primary Routes of Exposure: Contact with skin and eyes. Dust inhalation.
Eye Contact: May cause slight to mild irritation of the eyes.
Skin Contact: May cause slight to moderate irritation of the skin. May cause sensitization by skin contact. Thermal burns may occur upon ignition.
Inhalation: Dust or fumes may be irritating to the nose, mucous membranes and respiratory tract. Individuals hypersensitive to nickel may develop wheezing.
Ingestion: Harmful if swallowed. Ingestion of large amounts may cause gastrointestinal irritation, nausea, vomiting and headache.
Acute Health Effects: May cause sensitization by skin contact. May be irritating to skin, eyes and respiratory tract.
Chronic Health Effects: Possible harm to the unborn child and possible risk of irreversible effects. May cause cancer. (Animal studies with nickel powder surgically instilled or implanted for long periods in lungs, trachea, under skin, - see NTP and IARC discussions)
NTP: Yes
IARC: Yes
OSHA: No
SECTION 4: First Aid Measures
Eye Exposure: Immediately flush the eyes with copious amounts of water for at least 10-15 minutes. A victim may need assistance in keeping their eye lids open. Get immediate medical attention.
Skin Exposure: Wash the affected area with water. Remove contaminated clothes if necessary. Seek medical assistance if irritation persists.
Inhalation: Remove the victim to fresh air. Closely monitor the victim for signs of respiratory problems, such as difficulty in breathing, coughing, wheezing, or pain. In such cases seek immediate medical assistance.
Ingestion: Seek medical attention immediately. Keep the victim calm. Give the victim water (only if conscious). Induce vomiting only if directed by medical personnel.
SECTION 5: Fire Fighting Measures
Flash Point: not applicable
Autoignition Temperature: no data
Explosion Limits: no data
Extinguishing Medium: Water or dry sand
Special Fire Fighting Procedures: No special firefighting procedures required for this product.
Hazardous Combustion and Decomposion Products: none
Unusual Fire or Explosion Hazards: Not a hazard while wet with water. Pyrophoric if allowed to dry
SECTION 6: Accidental Release Measures
Spill and Leak Procedures: Small spills can be mixed with vermiculite, ground limestone or soda ash and swept up.
SECTION 7: Handling and Storage
Handling and Storage: Store in a tightly sealed container
SECTION 8: Exposure Controls and Personal Protection
Eye Protection: Always wear approved safety glasses when handling a chemical substance in the laboratory.
Skin Protection: Wear protective clothing and gloves.
Ventilation: Handle the material in an efficient fume hood.
Respirator: If ventilation is not available a respirator should be worn. The use of respirators requires a Respirator Protection Program to be in compliance with 29 CFR 1910.134.
Additional Protection: No additional protection required.
SECTION 9: Physical and Chemical Properties
Color and Form: black powder, (d50=35 microns)
Molecular Weight: not applicable
Melting Point: no data
Boiling Point: 100°C (water)
Vapor Pressure: no data
Specific Gravity: no data
Odor: none
Solubility in Water: insoluble
SECTION 10: Stability and Reactivity
Stability: air and moisture stable
Hazardous Polymerization: no hazardous polymerization
Conditions to Avoid: Mixtures of fine dust with air, contact with ignition sources.
Incompatibility: Mineral acids, halogens, acetylene, hydrazinium nitrate and oxidizing agents, sulfur.
Decomposition Products: none
SECTION 11: Toxicological Information
RTECS Data: Oral (rat); LDLo: 5g/kg. Intraperitoneal (rat); LD50: 250mg/kg. Intratracheal (rat); LDLo: 12mg/kg. Intravenous (mouse); LDLo: 50mg/kg. Subcutaneous (cat); LDLo: 12500ug/kg. Intraperitoneal (rabbit); LDLo: 7mg/kg. Inhalation (rat); TCLo: 100ug/m3/24H/17W-I. Oral (mouse); TDLo: 500mg/kg/5D-I. Subcutaneous (rat); TDLo: 2000mg/kg/6W-I. Intraperitoneal (rat); TDLo: 100mg/kg/21W-I. Hampster kidney; morphological transformation: 400mg/L.
Carcinogenic Effects: Tumorigen
Mutagenic Effects: Mutagen
Tetratogenic Effects: Reproductive effector
SECTION 12: Ecological Information
Ecological Information: No information available
SECTION 13: Disposal Considerations
Disposal: Dispose of according to local, state and federal regulations.
SECTION 14: Transportation
Shipping Name (CFR): Metal catalyst, Wetted
Hazard Class (CFR): 4.2
Additional Hazard Class (CFR): NA
Packaging Group (CFR): II
UN ID Number (CFR): UN# 1378
Shipping Name (IATA): Metal catalyst, Wetted
Hazard Class (IATA): 4.2
Additional Hazard Class (IATA): NA
Packaging Group (IATA): II
UN ID Number (IATA): UN# 1378
SECTION 15: Regulatory Information
TSCA: Listed in the TSCA inventory
SARA (Title 313): Reportable under SARA Title 313.
Second Ingredient: none
Third Ingredient: none
SECTION 16: Other Information
Disclaimer: The information herein is believed to be accurate and reliable as of the date compiled. However, Strem Chemicals, Inc. makes no representation, warranty, or guarantee of any kind with respect to the information contained in this document or any use of the product based on this information.
Preparation Date: 10/12/2004
Revision Date: 12/19/2011

Enter a lot number