Search for a full or partial Catalog Number, CAS Number or description
Your favorites Quick Order Form
Your cart is empty.
Home Catalog New Products Custom Synthesis & CGMP Product Resources About
Contact Strem

Product Catalog

13-1900
Aluminum Triethyl(tri-sec-butoxy)dialuminum (contains diethyl(tetra-sec-butoxy)dialuminum and tetraethyl(di-sec-butoxy)dialuminum)
CAS Number:
MDL Number: MFCD01631272
Molecular Formula: C18H42Al2O3
Molecular Weight:  
Chemical Formula: (C2H5)3Al2(OC4H9)3
Color and Form: colorless liq.
Note:  

Stability: air sensitive, moisture sensitive

Safety: Hazardous

Physical Characteristics: boiling point 183-186°C/40mm

Please log in or choose your country below to view prices.

Choose Your Country

SECTION 1: Product Identification
Chemical Name: Triethyl(tri-sec-butoxy)dialuminum(contains diethyl(tetra-sec-butoxy)dialuminum and tetraethyl(di-sec-butoxy)dialuminum
Product Number: 13-1900
CAS Registry Number: not available
Formula: (C2H5)3Al2(OC4H9)3
EINECS Number: none
Chemical Family: metal alkyl
Synonym: tri-sec-butoxytriethyldialuminum
SECTION 2: Composition and Information on Ingredients
Ingredient CAS Number Percent ACGIH (TWA) OSHA (PEL)
Title Compound not available 100 2mg/m3 (Al sol.) no data
SECTION 3: Hazards Identification
Emergency Overview: May be irritating to skin, eyes, and respiratory tract. May be harmful if swallowed.
Primary Routes of Exposure: Ingestion, inhalation, skin, eyes
Eye Contact: May cause mild to moderate irritation of the eyes.
Skin Contact: May cause slight to mild irritation of the skin.
Inhalation: May be irritating to the nose, mucous membranes and respiratory tract.
Ingestion: No specific information is available on the physiological effects of ingestion.
Acute Health Effects: Material may be irritating to skin, eyes, and mucous membranes.
Chronic Health Effects: The chronic toxicological properties of this compound have not been thoroughly investigated. Unrecognized hazards may be present.
NTP: No
IARC: No
OSHA: No
SECTION 4: First Aid Measures
Eye Exposure: Immediately flush the eyes with copious amounts of water for at least 10-15 minutes. A victim may need assistance in keeping their eye lids open. Get immediate medical attention.
Skin Exposure: Wash the affected area with water. Remove contaminated clothes if necessary. Seek medical assistance if irritation persists.
Inhalation: Remove the victim to fresh air. Closely monitor the victim for signs of respiratory problems, such as difficulty in breathing, coughing, wheezing, or pain. In such cases seek immediate medical assistance.
Ingestion: Seek medical attention immediately. Keep the victim calm. Give the victim water (only if conscious). Induce vomiting only if directed by medical personnel.
SECTION 5: Fire Fighting Measures
Flash Point: not applicable
Autoignition Temperature: no data
Explosion Limits: no data
Extinguishing Medium: dry chemical, carbon dioxide, water, or foam.
Special Fire Fighting Procedures: Fire fighters should be equipped with a NIOSH approved positive pressure self-contained breathing apparatus and full protective clothing.
Hazardous Combustion and Decomposion Products: If involved in a fire this material may emit toxic and corrosive fumes.
Unusual Fire or Explosion Hazards: Highly flammable. Formation of explosive air/vapor mixtures is possible.
SECTION 6: Accidental Release Measures
Spill and Leak Procedures: Small spills can be mixed with vermiculite, sodium carbonate or other suitable non-combustible adsorbent and swept up. Product reacts with water.
SECTION 7: Handling and Storage
Handling and Storage: Handle and store the material under an inert atmosphere of nitrogen or argon. Keep away from heat.
SECTION 8: Exposure Controls and Personal Protection
Eye Protection: Always wear approved safety glasses when handling a chemical substance in the laboratory.
Skin Protection: Wear protective clothing and gloves. Consult with glove manufacturer to determine the proper type of glove.
Ventilation: If possible, handle the material in an efficient fume hood.
Respirator: If ventilation is not available a respirator should be worn. The use of respirators requires a Respirator Protection Program to be in compliance with 29 CFR 1910.134.
Additional Protection: No additional protection required.
SECTION 9: Physical and Chemical Properties
Color and Form: colorless liq.
Molecular Weight: not applicable
Melting Point: no data
Boiling Point: 183-186°C/40mm
Vapor Pressure: no data
Specific Gravity: no data
Odor: none
Solubility in Water: reacts with water
SECTION 10: Stability and Reactivity
Stability: air sensitive, moisture sensitive
Hazardous Polymerization: no hazardous polymerization
Conditions to Avoid: Heat and ignition sources.
Incompatibility: Oxidizing agents, water, active metals and halogens
Decomposition Products: Aluminum oxide, sec-butanol, (in presence of moisture), carbon monoxide, carbon dioxide, and organic fumes.
SECTION 11: Toxicological Information
RTECS Data: No information available in the RTECS files.
Carcinogenic Effects: no data
Mutagenic Effects: no data
Tetratogenic Effects: no data
SECTION 12: Ecological Information
Ecological Information: No information available
SECTION 13: Disposal Considerations
Disposal: Dispose of according to federal, state, and local regulations.
SECTION 14: Transportation
Shipping Name (CFR): Flammable liquids, N.O.S.
Hazard Class (CFR): 3
Additional Hazard Class (CFR): NA
Packaging Group (CFR): II
UN ID Number (CFR): UN# 1993
Shipping Name (IATA): Flammable liquid, N.O.S.
Hazard Class (IATA): 3
Additional Hazard Class (IATA): NA
Packaging Group (IATA): II
UN ID Number (IATA): UN# 1993
SECTION 15: Regulatory Information
TSCA: Not listed in the TSCA inventory.
SARA (Title 313): Title compound not listed.
Second Ingredient: none
Third Ingredient: none
SECTION 16: Other Information
Disclaimer: The information herein is believed to be accurate and reliable as of the date compiled. However, Strem Chemicals, Inc. makes no representation, warranty, or guarantee of any kind with respect to the information contained in this document or any use of the product based on this information.
Preparation Date: 8/18/2002
Revision Date: 12/14/2011

Enter a lot number